UVC Max 25 110V Whole House Air Purifier

$149.95

This high efficiency purifier uses a UV-C (germicidal) lamp to destroy chemical & biological contaminants including chemical odors. It can be used in any kind of building including homes, commercial spaces, offices, schools, hospitals, etc.

Category: SKU: FG0260

Description

UVC The UVC MAX 25 unit is designed to emit powerful ultraviolet light rays, which sterilize and reduce airborne microorganisms as they pass through a home heating and air conditioning system.

The UVC Max 25 is installed in the main air supply or return duct of the home system, and operates continuously to automatically purify air in the home 24 hours a day.

 

  • Produces no ozone
  • 1 year warranty
  • 12,000 hours bulb life
  • Replacement bulbs available

Size (unit without bulb): 6.5″ x 2″ x 4.5″
Weight: 3 lbs

Duct Board System Installation

Aluminum System Installation

Installation Instructions

WARNING: TO PREVENT SERIOUS INJURY, DO NOT PLUG-IN AND TURN ON LIGHT UNTIL AFTER IT HAS BEEN COMPLETELY INSTALLED.

Types of A/C – Furnace Units

Example of a typical “A-Frame” coil cooling unit.

Example of a typical “Flat or Vertical”  cooling coil unit.

Installing in a Metal Duct Unit

Step 1

When the proper location for the UVC MAX 25 has been selected, cut open a 3″ hole in the center of the duct.

Step 2

Insert the UVC MAX 25.

Step 3

Place screws and drive screws into metal.

Step 4

Plug in the UVC MAX 25

(24 volt transformer option included for contractor installation)

Installing in a Duct Board Unit

Step 1

When the proper location for the UVC MAX 25 has been selected, use the duct board mounting plate (5”x7” overall) to draw lines where the duct board must be cut 3” wide by 4 1/4” tall.

Step 2

Cut the rectangular hole and remove the loose piece of duct board or aluminum duct.

Step 3

Place the mounting plate over the access hole.

Step 4

Bend the mounting plate 90 degrees at the first score point.

Do the same for the bottom score point.

Step 5

Bend the mounting plate 90 degrees at the second score point.

Do the same for the bottom second score point.

Step 6

Insert to UVC MAX 25 into the mounting plate access.

Step 7

Insert the 4 screws provided into the mounting plate corner holes.

Step 8

Plug the UVC MAX 25 into a nearby socket.

(24 volt transformer option included for contractor installation)

Additional information

Weight 2.2 lbs
Dimensions 12.75 × 10.25 × 4 in